    Модель SIC-9W-R2 SIC-14W-R2 SIC-21W-R2 SIC-28W-R2 SIC-33W-R2 SIC-42W-R2 SIC-56W-R2 SIC-66W-R2 SIC-84W-R2 SIC-112W-R2 SIC-126W-R2 SIC-132W-R2
    kW (outlet temperature 7°C/44.6°F of chilled water under the temperature of 30°C/86°F and flow of 0.215m3/(h.kW) of cooling water) 50Hz 12.5 18.5 33 37 43 55 74 87 110 148 166 174
    Cooling Capacity (kW, outlet temperature 7°C/44.6°F of chilled water under the temperature of 30°C/86°F and flow of 0.215m3/(h.kW) of cooling water) 60Hz 10.8 16.8 25.2 33.6 39.6 50.4 67.2 79.2 100.8 134.4 151.2 158.4
    Cooling Capacity (kW, outlet temperature 15°C/59 F of chilled water under the temperature of 25°C/77°F and flow of 0.215m3/(h.kW) of cooling water) 60Hz 15 22.2 39.6 44.4 51.6 66 88.8 104.4 132 177.6 199.2 208.8
    Compressor (Power, kW) Type Scroll
    50Hz 2.5 3.55 5.5 7.35 8.35 10.5 14.7 16.7 21 28.35 31.5 33.4
    60Hz 3.2 4.5 6.4 8.5 9.75 12.5 17 19.5 25 33.5 37.5 39
    Refrigerant kg 2.5 3.0 5.5 5.5 9.8 8.7 10.8 16 17.4 21.4 26.1 32
    lb 5.5 6.6 12.1 12.1 21.6 19.2 23.8 35.3 38.4 47.2 57.5 70.5
    Control Mode Thermostatic expansion valve
    Type R410A
    Evaporator (Type) 50Hz Tube-in-shell style
    60Hz Plate style Plate style Plate style Plate style Plate style Plate style Plate style Plate style Plate style Tube-in-shell style Tube-in-shell style Tube-in-shell style
    Condenser Type Tube-in-shell style
    Condenser (In/out Pipe) inch 1 1/2 1 1/2 1 1/2 1 1/2 2 2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2x2 1/2
    Condenser (Cooling Water Flow) L/min 33.5 52.2 78.3 104.3 123 156.5 208.7 246 313 417.4 469.6 491.9
    gal/min 8.9 13.8 20.7 27.6 32.5 41.3 55.1 65.0 82.7 110.3 124.0 129.9
    Water Tank L 40 40 70 70 80 80 200 200 200 400 400 400
    gal 10.6 10.6 18.5 18.5 21.1 21.1 52.8 52.8 52.8 105.7 105.7 105.7
    Pump (Power, kW) 50Hz 0.75/0.75/1.1 0.75/0.75/1.1 1.1/1.1/1.1 1.1/1.1/1.1 1.1/1.5/2.2 1.1/1.5/2.2 -/1.8/2.4 -/1.8/2.4 -/3.0/4.0 -/3.0/4.0 -/4.0/5.5 -/4.0/5.5
    60Hz 0.75/0.75/1.1 0.75/0.75/1.1 1.1/1.1/1.5 1.1/1.1/1.5 2.2 2.2 3 3 5 5 5 5
    Pump Flow (L/min ) 50Hz 25.8 40.1 60.2 80.3 94.6 120.4 160.5 189.2 240.8 321.1 361.2 378.4
    60Hz 30.9 48 71.9 96 113 147.2 191.7 226 287.7 383.6 431.6 452.2
    Pump (Working Pressure, kgf/cm2) 50Hz 3.3/3.7/4.5 3.1/3.5/4.3 2.8/3.9/5.7 2.7/3.3/4.0 2.7/3.7/4.7 2.6/3.5/4.5 -/3.2/4.4 -/3.1/4.1 -/3.4/4.1 -/2.8/3.8 -/3.7/4.4 -/3.2/4.3
    60Hz -/3.50/5.4 -/2.90/5 -/3.35/4.5 -/3.90/- -/4.0/5.4 -/5.0/6.2 -/4.2/5.1 -/4.4/- - - - -
    Total Power (kW) 50Hz 3.25 4.3 6.61 8.45 9.45 11.6 16.9 18.9 23.2 30.55 32.7 35.6
    60Hz 3.15 5.6 7.22 9.21 11.39 14.6 19.22 21.38 30.3 38.41 42.7 42.26
    Pipe Coupling (female thread) Chilled Water Outlet 1"G 1"G 1 1/2"G 1 1/2"G 2"G 2"G 2"G 2"G 2 1/2"G 2 1/2"G 2 1/2"G 2 1/2"G
    Chilled Water Inlet 1"G 1"G 1 1/2"G 1 1/2"G 2"G 2"G 2"G 2"G 2 1/2"G 2 1/2"G 2 1/2"G 2 1/2"G
    Drainage Port Of Water Tank 1/2"G 1/2"G 1/2"G 1/2"G 1/2"G 1/2"G 1/2"G 1/2"G 1/2"G 1"G 1"G 1"G
    Overflow Port Of Water Tank 1/2"G 1/2"G 1/2"G 1/2"G 1/2"G 1/2"G 1/2"G 1/2"G 1/2"G 1"G 1"G 1"G
    Protective Device Compressor Overload relay
    Pump Overload relay
    Refrigerant Circuit High and low pressure switches/Anti-freezing switch
    Cooling water Ciucuit By-pass valve/Water level switch (Option)
    Operation Noise dB(A) 69 70.5 70.4 72.5 71.4 74 75.5 73.3 78.5 71.41 79.6 86.5
    Power ЗФ, 230 / 400 / 460 / 575VAC, 50/60Hz
    Unit Conversion 1kW=860kcal/hr 1RT=3,024kcal/hr 10,000Btu/hr=2,520kcal/hr
    Цена
     

    ■ Features

    • Cooling temperature range 7~25°C/44.6~77°F.
    • Insulated water tank made of stainless steel.
    • Equipped with anti-freeze thermostat.
    • R410A ozone-friendly refrigerant.
    • Refrigeration loop controlled by high and low pressure switches to ensure stable operation.
    • Compressor and pump overload protection.
    • Adopt high precision temperature controller with a max precision of +/- 1°C/1.8 F.
    • All adopt quality compressors from major suppliers.
    • SIC-W-R2 adopts a tube-in-shell condenser with excellent heat transfer and resistance to lower water quality.
    • Equipped with hot-gas bypass valve for precision temperature control without the need to frequent the ON/OFF cycle.
    • Equipped with RS485 communication interface to realize centralized monitoring.

    Рисунок2.jpg


    ■ Options

    • For models with a medium-pressure pump, add "P" at the end of the model code, and for models optional with a high-pressure pump, add "HP" at the end of the model code.
    • The level sensor in water tank is optional to check whether the water level is within normal range, and add "SG" at the end of the model code.
    • Liquid solenoid valve for pump down a refrigerant circuit to avoid liquid migration back to the compressor on the off-cycle. It can potentially prevent liquid slug on startup. Add "LS" at the end of the model code.
    • Optional refrigerant indicator the refrigerant moisture content, and add "LS" at the end of the model code.
    • The flow switch is optional to ensure that the unit runs under sufficient water, and add "FW" at the end of the model code.


    ■ Application

    SIC-A-R2 series are applicable for cooling moulds to reduce the product moulding cycle; they are also available in the cooling of equipment to maintain a normal temperature. Besides, they are suitable for other industries with the need for water cooling.


    ■ Working Principle

    Рисунок3.jpg


    ■ Structure of SIC-W-R2

    Рисунок4.jpg
    Outline Drawings

    Рисунок5.jpg
    Рисунок6.jpg
    Рисунок7.jpg


    Dimensions

    Рисунок8.jpg

    Model Selection Reference

    Рисунок9.jpg
    Рисунок10.jpg

    Похожие товары